Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Rated Power: | 330V |
| Charging Current: | 15A/15A |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency


Single phase Hybrid Inverter-IP21 (1.2kW~12kW) | |||||
Model | ADC-1P12V1.2KW | ADC-1P12V2.5KW | ADC-1P24V3.6KW | ADC-1P48V6.5KW | ADC-1P48V12KW |
AC INPUT | |||||
Rated Input Voltage (VAC) | 220/230/240;L+N+PE | ||||
Voltage Range (VAC) | 90~280±3(normal mode);170~280±3(UPS mode) | ||||
Frequency (HZ) | 50/60(Auto Adaptive) | ||||
AC OUTPUT | |||||
Rated Capacity (kW) | 1.2 | 2.5 | 3.6 | 6.5 | 12 |
Voltage (VAC) | 220/230/240+/-5% | ||||
Frequency | 50/60Hz ±0.1% | ||||
Charger (PV/AC) | |||||
Solar Charger Type | MPPT | MPPT | MPPT | MPPT | Dual MPPTs |
Max PV Input Current / Power | 18A / 800W | 18A / 3000W | 18A / 5000W | 27A / 9000W | 2*7500W = 15KW |
Battery | |||||
Normal Voltage (VDC) | 12 | 12 | 24 | 48 | 48 |
Floating Charge Voltage (VDC) | 13.8 | 13.8 | 27 | 54 | 54 |
Overcharge Protection(VDC) | 15 | 15 | 30.5 | 61 | 61 |
Battery Type | Lead-acid / Lithium | ||||
Interface | |||||
HMI | LCD | ||||
Interface | RS232/RS485 (Optional)/CAN (Optional) | RS232 / RS485 / CAN | |||
Monitoring | WiFi Optional | Built-in WiFi / External WiFi (optional) | |||
Single phase Hybrid Inverter-IP65 (3kW~8kW) | |||||
Model | ADC-S1P48V3K-65 | ADC-S1P48V3.68K-65 | ADC-S1P48V7.5K-65 | ADC-S1P48V6K-65 | ADC-S1P48V8K-65 |
Efficiency | |||||
Maximum Efficiency | 97.60% | 97.60% | 97.60% | 97.60% | 97.60% |
European Efficiency | 97.00% | 97.00% | 97.00% | 97.00% | 97.00% |
MPPT Efficiency | 98.90% | 98.90% | 98.90% | 98.90% | 98.90% |
Maximum charging/discharging efficiency | 94.30% | 94.30% | 94.20% | 94.00% | 94.00% |
DC Input (Photovoltaic) | |||||
Maximum Input Power | 4500W | 5500W | 7500W | 9000W | 12000W |
Maximum DC Input Voltage | 550V | ||||
MPPT Voltage Range | 90V–550V | ||||
Rated Input Voltage | 360V | ||||
AC Input (Grid) / Output (Off-grid) | |||||
Rated Output Power | 3000W | 3680W | 5000W | 6000W | 8000W |
Maximum Apparent Power | 3300VA | 4048VA | 5500VA | 6600VA | 8800VA |
Rated Grid Voltage | 220V/230V , L+N+PE | ||||
Rated Grid Frequency/Range | 50Hz/60Hz , ±5Hz | ||||
Maximum Grid Input Power | 9000W | ||||
Maximum Grid Bypass Current | 41A | ||||
Battery Parameters | |||||
Battery Type | Lithium battery / Lead-acid battery | ||||
Battery Voltage Range | 40V–60V | ||||
Rated Battery Voltage | 48V | ||||
Three phase Hybrid Inverter-IP65 (10kW~15kW) | |||
Model | ADC-S3P48V10K-65 | ADC-S3P48V12K-65 | ADC-S3P48V15K-65 |
Efficiency | |||
Maximum efficiency | 97.6% | ||
European efficiency | 97.0% | ||
DV(PV) Input | |||
Max. PV input power | 16kW | 19.2kW | 24kW |
Rated input voltage | 550V | ||
Start-up voltage | 150V | ||
MPPT voltage range | 160-850V | ||
MPPT quantity/Max.number of input channels | 2/3 | 2/4 | |
Battery | |||
Battery type | Lithium battery/lead-acid battery | ||
Rated battery voltage | 48V | ||
Max. charging/discharging current | 210A | 250A | 310A |
Communication method | CAN / RS485 | ||
AC Input (on-grid) | |||
Input voltage range | 323-460V | ||
Max. input current | 22.8A/21.7A | 27.3A/26A | 34.2A/32.5A |
Frequency range | 50Hz/60Hz, ±5Hz | ||
AC Output (off-grid) | |||
Rated output power | 10kW | 12kW | 15kW |
Rated output voltage | 220V/380V, 230V/400V, 3L+N+PE | ||
Rated frequency | 50Hz/60Hz | ||
Max. output current | 15.2A/14.4A | 18.2A/17.3A | 22.8A/21.7A |
Max. continuous output current | 15.2A | 18.2A | 22.8A |
Max. continuous bypass current | 45A | ||
Generator Input | |||
Max. input power | 10kW | 12kW | 15kW |
Max. input current | 15.2A | 18.2A | 22.8A |
Rated input voltage | 220V/380V, 230V/400V, 3L+N+PE | ||
Rated input frequency | 50Hz/60Hz | ||